67 research outputs found

    Sequential modular position and momentum measurements of a trapped ion mechanical oscillator

    Full text link
    The non-commutativity of position and momentum observables is a hallmark feature of quantum physics. However this incompatibility does not extend to observables which are periodic in these base variables. Such modular-variable observables have been suggested as tools for fault-tolerant quantum computing and enhanced quantum sensing. Here we implement sequential measurements of modular variables in the oscillatory motion of a single trapped ion, using state-dependent displacements and a heralded non-destructive readout. We investigate the commutative nature of modular variable observables by demonstrating no-signaling-in-time between successive measurements, using a variety of input states. In the presence of quantum interference, which we enhance using squeezed input states, measurements of different periodicity show signaling-in-time. The sequential measurements allow us to extract two-time correlators for modular variables, which we use to violate a Leggett-Garg inequality. The experiments involve control and coherence of multi-component superpositions of up to 8 coherent, squeezed or Fock state wave-packets. Signaling-in-time as well as Leggett-Garg inequalities serve as efficient quantum witnesses which we probe here with a mechanical oscillator, a system which has a natural crossover from the quantum to the classical regime.Comment: 6 pages, 3 figures and supplemental informatio

    Time-dependent Hamiltonian estimation for Doppler velocimetry of trapped ions

    Full text link
    The time evolution of a closed quantum system is connected to its Hamiltonian through Schroedinger's equation. The ability to estimate the Hamiltonian is critical to our understanding of quantum systems, and allows optimization of control. Though spectroscopic methods allow time-independent Hamiltonians to be recovered, for time-dependent Hamiltonians this task is more challenging. Here, using a single trapped ion, we experimentally demonstrate a method for estimating a time-dependent Hamiltonian of a single qubit. The method involves measuring the time evolution of the qubit in a fixed basis as a function of a time-independent offset term added to the Hamiltonian. In our system the initially unknown Hamiltonian arises from transporting an ion through a static, near-resonant laser beam. Hamiltonian estimation allows us to estimate the spatial dependence of the laser beam intensity and the ion's velocity as a function of time. This work is of direct value in optimizing transport operations and transport-based gates in scalable trapped ion quantum information processing, while the estimation technique is general enough that it can be applied to other quantum systems, aiding the pursuit of high operational fidelities in quantum control.Comment: 10 pages, 8 figure

    A dynamic magneto-optical trap for atom chips

    Get PDF
    We describe a dynamic magneto-optical trap (MOT) suitable for the use with vacuum systems in which optical access is limited to a single window. This technique facilitates the long-standing desire of producing integrated atom chips, many of which are likely to have severely restricted optical access compared with conventional vacuum chambers. This "switching-MOT" relies on the synchronized pulsing of optical and magnetic fields at audio frequencies. The trap's beam geometry is obtained using a planar mirror surface, and does not require a patterned substrate or bulky optics inside the vacuum chamber. Central to the design is a novel magnetic field geometry that requires no external quadrupole or bias coils which leads toward a very compact system. We have implemented the trap for 85Rb and shown that it is capable of capturing 2 million atoms and directly cooling below the Doppler temperature

    Development of automatic intelligent system for on-line voltage security control of power systems

    Get PDF
    The majority of recent large-scale blackouts have been caused by voltage instability. A prompt on-line assessment of voltage stability for preventive corrective control of electric power systems is one of the key objectives for Control centers. The use of classical approximation methods alone is complicated. Therefore, several modified methods combined with machine learning algorithms enabling security assessment in real time have been proposed over the last years. The paper presents an automatic intelligent system for on-line voltage security control, which is based on the model of decision trees Proximity Driven Streaming Random Forest (PDSRF). In this case, the combination of original properties of PDSRF and capabilities of L-index as a target vector makes it possible to provide the functions of dispatcher warning, localization of critical nodes, and ensure direct interaction with the security automation systems. The efficiency of the proposed system was demonstrated using various test schemes of IEEE

    Coherent Control of Trapped Ion Qubits with Localized Electric Fields

    Full text link
    We present a new method for coherent control of trapped ion qubits in separate interaction regions of a multi-zone trap by simultaneously applying an electric field and a spin-dependent gradient. Both the phase and amplitude of the effective single-qubit rotation depend on the electric field, which can be localised to each zone. We demonstrate this interaction on a single ion using both laser-based and magnetic field gradients in a surface-electrode ion trap, and measure the localisation of the electric field

    Benchmarking the performance of a low-cost Magnetic Resonance Control System at multiple sites in the open MaRCoS community

    Full text link
    Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and different types of software interfaces (custom-built GUI or PulSeq overlay) to acquire the data. Results: Images are presented from both phantoms and in vivo from healthy volunteers to demonstrate the image quality that can be obtained from the MaRCoS hardware/software interfaced to different low-field magnets. Conclusions: The results presented here show that a number of different sequences commonly used in the clinic can be programmed into an open-source system relatively quickly and easily, and can produce good quality images even at this early stage of development. Both the hardware and software will continue to develop, and it is an aim of this paper to encourage other groups to join this international consortium.Comment: 9 pages, 10 figures, comments welcom
    corecore